Guides / Power station for a gas furnace

What size power station runs a gas furnace

Some links on this page go to Amazon. If you buy through them, we earn a commission. It doesn't change your price.

A gas furnace needs electricity for its blower and controls. Size for the start-up surge first, then for the hours you need heat.

Electrician required

Furnaces are hard-wired. Power one from a battery only through an inlet and transfer switch fitted by a licensed electrician. Never run a fuel generator indoors or in a garage.

Our pick

BLUETTI Elite 200 V2

Best for a winter night

Capacity
2,073.6 Wh
Output
2,600 W
Voltage
120 V

2,600 watts continuous and a 5,200-watt surge, with 2,073.6 Wh: about 9 hours of a typical blower running 35% of the time. Connect it through an inlet and transfer switch fitted by an electrician.

Not for: 240-volt well pumps and other 240-volt loads, or more than about a day of essentials without a recharge.

PickCapacityMeasured usableOutputBuy
Best for a winter nightBLUETTI Elite 200 V22,073.6 WhNot measured2,600 WCheck price on Amazon
Best for a short outage or efficient blowerAnker SOLIX C1000 Gen 21,024 Wh890 Wh2,000 WCheck price on Amazon

A gas or propane furnace burns fuel, but it can't heat a house without electricity. The blower, draft inducer, igniter and control board all need power. That load is small next to a refrigerator and a pump, which is why a mid-size power station can cover a winter night. The harder parts are the start-up surge and connecting it safely.

Size a battery for your furnace

In a cold snap a furnace may run a third to half of the time. Watch your thermostat on a cold day to see yours.

Your result

Wh

Battery to buy

Energy used
Wh
Running watts
W
Starting surge
W

Typical figures. Your furnace's rating plate gives the real amps. The calculator adds 10 watts of standby draw all night.

Assumes: 85% of rated capacity is usable. The blower runs for the share of each hour you set, plus 10 watts for the controls. Start-up surge is 3 times running watts.

Work out your number

  1. Find the rating plate. It is inside the furnace cabinet. Note the blower motor amps and the circuit amps.
  2. Allow for the start. The inducer, igniter and blower start together. Sources put the combined surge at 1,000 to 2,000 watts.
  3. Estimate how often it runs. In deep cold the furnace cycles more. Use the share of time it runs, not a full 24 hours.
  4. Multiply and add headroom. Running watts, times the share of time, times hours, plus standby. Then divide by 0.85, the usable share of a battery.

500 W × 35% × 8 hours = 1,400 Wh. Add 10 W of standby for 8 hours (80 Wh) for 1,480 Wh. Divide by 0.85 and round up to the next 100: a 1,800 Wh battery.

What a furnace draws

PhaseTypical draw
RunningAbout 300 to 600 W; older motors 500 to 700 W
Start-up surgeAbout 1,000 to 2,000 W together
StandbyAbout 5 to 15 W

Connecting it safely

Most furnaces are hard-wired. You usually can't plug one into a power station like a lamp. Plan on a power inlet with a transfer switch or interlock, installed by an electrician and permitted where required. Our guides to connecting a power station to your house and transfer switch vs interlock kit explain the options.

Never backfeed. Don't plug a power station into a wall outlet to feed the house wiring.

Check your carbon monoxide detectors. Many plug-in models stop working when the power is out. Use battery-backed detectors, and never run a gas generator indoors.

Electric heat is a different problem. Heat pumps, electric furnaces and space heaters draw thousands of watts. A power station is not sized for them for long.

Why we picked these

Chosen from manufacturer specifications and independent bench tests. We haven't tested these ourselves. Trade-offs and limits are drawn from the same published specifications and bench tests.

Fits your resultBest for a short outage or efficient blower

Anker SOLIX C1000 Gen 2 Portable Power Station

Capacity
1,024 Wh
Measured usable
890 Wh
Output
2,000 W

2,000 watts continuous and 3,000 at peak is well above a typical furnace's start. At 1,024 Wh, it suits a few hours of heat or an efficient blower. Plan on solar or a recharge for a long cold snap.

Trade-off
Capacity is the limit. 1,024 Wh suits hours, not days, unless you can recharge.
Not for
Loads above 2,000 running watts, or outages you need to ride out for days on one charge.
Fits your resultBest for a winter night

BLUETTI Elite 200 V2 Portable Power Station

Capacity
2,073.6 Wh
Output
2,600 W
Voltage
120 V

2,600 watts continuous and a 5,200-watt surge, with 2,073.6 Wh: about 9 hours of a typical blower running 35% of the time. Connect it through an inlet and transfer switch fitted by an electrician.

Trade-off
It is a 120-volt unit, so it cannot run 240-volt equipment.
Not for
240-volt well pumps and other 240-volt loads, or more than about a day of essentials without a recharge.
Capacity
Energy stored, as the maker rates it.
Measured usable
Energy an independent test got out.
Output
Watts it can supply continuously.
Voltage
240 V runs most well pumps.